Removing a memory module – Lenovo ThinkServer TD200x User Manual

Page 100

Advertising
background image

6. Close the bezel (see “Closing the bezel” on page 98).

Removing a memory module

1

DIMM

2

Retaining clip

To remove a dual inline memory module (DIMM), do the following:

1. Read the safety information that begins on page vii and “Handling

static-sensitive devices” on page 39.

2. Turn off the server and peripheral devices, and disconnect the power cords

and all external cables.

3. Turn the server on its side so that it is lying flat, with the cover facing up.

4. Unlock and remove the left-side cover (see “Removing the left-side cover” on

page 42).

5. Remove the hot-swap power supply or power supplies from the power-supply

cage (see “Removing a hot-swap power supply” on page 63).

6. Rotate the power-supply cage to its open position (see “Opening the

power-supply cage” on page 47).

7. Remove the air baffle (see “Removing the air baffle” on page 58).

8. Locate the DIMM connectors on the system board (see “System-board internal

connectors” on page 25).

Attention:

To avoid breaking the retaining clips or damaging the DIMM

connectors, handle the clips gently.

9. Move the DIMM retaining clips on the side of the DIMM connector to the open

position by pressing the retaining clips away from the center of the DIMM
connector.

10. Using your fingers, lift the DIMM out of the DIMM connector.

11. If you are instructed to return the DIMM, follow all packaging instructions, and

use any packaging materials for shipping that are supplied to you.

84

ThinkServer TD200x Types 3719, 3821, 3822, and 3823: Installation and User Guide

Advertising