Microprocessor problems

v

Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.

v

See the parts listing in the Hardware Maintenance Manual to determine which components are customer
replaceable units (CRUs) and which components are field replaceable units (FRUs).

v

If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.

Symptom

Action

The server emits a continuous
beep during POST, indicating
that the startup (boot)
microprocessor is not working
correctly.

1. Correct any errors that are indicated by the EasyLED diagnostics LEDs (see

“EasyLED diagnostics panel” on page 17).

2. Make sure that the server supports all the microprocessors and that the

microprocessors match in speed and cache size.

3. (Trained service technician only) Reseat microprocessor 1.

4. (Trained service technician only) If there is no indication of which

microprocessor has failed, isolate the error by testing with one microprocessor
at a time.

5. Replace the following components one at a time, in the order shown, restarting

the server each time:

a. (Trained service technician only) Microprocessor 2

b. VRM 2

c. (Trained service technician only) System board

6. (Trained service technician only) If multiple error codes or EasyLED diagnostics

LEDs indicate a microprocessor error, reverse the locations of two
microprocessors to determine whether the error is associated with a
microprocessor or with a microprocessor socket.

v

If the error is associated with a microprocessor, replace the microprocessor.

v

If the error is associated with a VRM, replace the VRM.

v

If the error is associated with a microprocessor socket, replace the system
board.

132

ThinkServer TD200x Types 3719, 3821, 3822, and 3823: Installation and User Guide