– On models with eight hard disk drives, the top bays are numbered 0 through 7

(from right to left)

– On models with 16 hard disk drives, the top bays are numbered 0 through 7

(from right to left) and the bottom bays are 8 through 15 (from right to left)

0

Bay 0

8

Bay 8

1

Bay 1

9

Bay 9

2

Bay 2

10

Bay 10

3

Bay 3

11

Bay 11

4

Bay 4

12

Bay 12

5

Bay 5

13

Bay 13

6

Bay 6

14

Bay 14

7

Bay 7

15

Bay 15

v

For a list of supported optional devices for the server, see
http://www.lenovo.com/thinkserver.

v

Inspect the drive and drive bay for signs of damage.

v

Make sure that the drive is correctly installed in the drive bay.

v

See the documentation for the ServeRAID controller for instructions for installing
a hard disk drive.

v

All hot-swap drives in the server must have the same throughput speed rating;
using drives with different speed ratings might cause all drives to operate at the
throughput of the slowest drive.

v

You do not have to turn off the server to install hot-swap drives in the hot-swap
drive bays. However, you must turn off the server when you perform any steps
that involve installing or removing cables.

v

The drive ID for each hot-swap hard disk drive is printed above the drive bay.