Lenovo ThinkServer TD200x User Manual

Page 179

Advertising
background image

v

Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.

v

See the "Parts Listing" section in the Hardware Maintenance Manual to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).

v

If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.

Sensor RAID Error has transitioned
to critical from a less severe state.

Error

A sensor has changed to
Critical state from a less
severe state.

1. Check the hard disk drive

LEDs.

2. Reseat the hard disk drive for

which the status LED is lit.

3. Replace the defective hard

disk drive.

The Drive n Status has been
removed from unit Drive 0 Status.
(n = hard disk drive number)

Error

A drive has been removed.

Reseat hard disk drive n.
(n = hard disk drive number)

The Drive n Status has been
disabled due to a detected fault.
(n = hard disk drive number)

Error

A drive has been disabled
because of a fault.

1. Run the hard disk drive

diagnostic test on drive n.

2. Reseat the following

components:

a. Hard disk drive

b. Cable from the system

board to the backplane

3. Replace the following

components one at a time, in
the order shown, restarting
the server each time:

a. Hard disk drive

b. Cable from the system

board to the backplane

c. Hard disk drive backplane

(n = hard disk drive number)

Array %1 is in critical condition.
(%1 = CIM_ComputerSystem.
ElementName)

Error

An array is in Critical state.
(Sensor = Drive n Status)
(n = hard disk drive number)

Replace the hard disk drive that
is indicated by a lit status LED.

Array %1 has failed.
(%1 = CIM_ComputerSystem.
ElementName)

Error

An array is in Failed state.
(Sensor = Drive n Status)
(n = hard disk drive number)

Replace the hard disk drive that
is indicated by a lit status LED.

Memory uncorrectable error detected
for DIMM All DIMMs on Memory
Subsystem All DIMMs.

Error

A memory uncorrectable
error has occurred.

1. If the server failed the POST

memory test, reseat the
DIMMs.

2. Replace any DIMM that is

indicated by a lit error LED.
Note: You do not have to
replace DIMMs by pairs.

3. Run the Setup utility to enable

all the DIMMs.

4. Run the DSA memory test.

Chapter 7. Troubleshooting

163

Advertising