Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.

v

See the "Parts Listing" section in the Hardware Maintenance Manual to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).

v

If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.

Sensor PS n VCO Fault has
transitioned to non-recoverable.
(n = power supply number)

Error

A sensor has changed to
Nonrecoverable state.

1. Check the power-supply LED

on the EasyLED diagnostics
panel (see “EasyLED
diagnostics panel” on page
17).

2. Replace the failing power

supply.

(n = power supply number)

Redundancy Power Unit has been
reduced.

Error

Redundancy has been lost
and is insufficient to continue
operation.

1. Check the LEDs for both

power supplies.

2. Follow the actions in

“Power-supply LEDs” on page
33.

Redundancy Cooling Zone 1 has
been reduced.

Error

Redundancy has been lost
and is insufficient to continue
operation.

1. Make sure that the connector

on fan 1 and fan 4 (if
installed) is not damaged.

2. Make sure that the fan

connectors on the system
board are not damaged.

3. Make sure that the fan cage

is correctly installed.

4. Reseat the fan.

5. Replace the fan.

Redundancy Cooling Zone 2 has
been reduced.

Error

Redundancy has been lost
and is insufficient to continue
operation.

1. Make sure that the connector

on fan 2 and fan 5 (if
installed) is not damaged.

2. Make sure that the fan

connectors on the system
board are not damaged.

3. Make sure that the fan cage

is correctly installed.

4. Reseat the fan.

5. Replace the fan.

Redundancy Cooling Zone 3 has
been reduced.

Error

Redundancy has been lost
and is insufficient to continue
operation.

1. Make sure that the connector

on fan 3 and fan 6 (if
installed) is not damaged.

2. Make sure that the fan

connectors on the system
board are not damaged.

3. Make sure that the fan cage

is correctly installed.

4. Reseat the fan.

5. Replace the fan.

162