Bryant Gas Furance 315AAV User Manual

Page 43

Advertising
background image

43

Table 14 -- Orifice Size and Manifold Pressure (In. W.C.) for Gas Input Rate (Con’t.)

(Tabulated Data Based on 22,000 Btuh High--Heat/14,500 Btuh for Low--Heat per Burner, Derated 4 Percent for Each 1000 Ft.

Above Sea Level)

ALTITUDE

RANGE

FT. (M)

AVG. GAS

HEAT VALUE

AT ALTITUDE

(BTUH/CU FT.)

SPECIFIC GRAVITY OF NATURAL GAS

0.58

0.60

0.62

0.64

Orifice

No.

Manifold

Pressure

High/Low

Orifice

No.

Manifold

Pressure

High/Low

Orifice

No.

Manifold

Pressure

High/Low

Orifice

No.

Manifold

Pressure

High/Low

USA

5001 to

6000

(1524

to

1829)

725

43

3.4/1.5

43

3.5/1.5

43

3.6/1.6

43

3.7/1.6

750

43

3.2/1.4

43

3.3/1.4

43

3.4/1.5

43

3.5/1.5

775

44

3.4/1.5

44

3.5/1.5

43

3.2/1.4

43

3.3/1.4

800

44

3.2/1.4

44

3.3/1.4

44

3.4/1.5

44

3.5/1.5

825

46

3.8/1.7

45

3.8/1.6

44

3.2/1.4

44

3.3/1.4

850

46

3.6/1.6

46

3.7/1.6

46

3.8/1.7

45

3.8/1.6

875

47

3.8/1.7

46

3.5/1.5

46

3.6/1.6

46

3.7/1.6

900

47

3.6/1.6

47

3.8/1.6

46

3.4/1.5

46

3.5/1.5

ALTITUDE

RANGE

FT. (M)

AVG. GAS

HEAT VALUE

AT ALTITUDE

(BTUH/CU FT.)

SPECIFIC GRAVITY OF NATURAL GAS

0.58

0.60

0.62

0.64

Orifice

No.

Manifold

Pressure

High/Low

Orifice

No.

Manifold

Pressure

High/Low

Orifice

No.

Manifold

Pressure

High/Low

Orifice

No.

Manifold

Pressure

High/Low

USA

6001 to

7000

(1829

to

2134)

675

43

3.4/1.5

43

3.5/1.5

43

3.6/1.6

43

3.7/1.6

700

44

3.6/1.6

43

3.3/1.4

43

3.4/1.5

43

3.5/1.5

725

44

3.4/1.5

44

3.5/1.5

44

3.6/1.6

43

3.2/1.4

750

45

3.8/1.7

44

3.3/1.4

44

3.4/1.5

44

3.5/1.5

775

46

3.7/1.6

45

3.7/1.6

45

3.8/1.7

44

3.2/1.4

800

46

3.5/1.5

46

3.6/1.6

46

3.8/1.6

45

3.7/1.6

825

47

3.7/1.6

46

3.4/1.5

46

3.5/1.5

46

3.6/1.6

850

47

3.5/1.5

47

3.6/1.6

47

3.8/1.6

46

3.4/1.5

ALTITUDE

RANGE

FT. (M)

AVG. GAS

HEAT VALUE

AT ALTITUDE

(BTUH/CU FT.)

SPECIFIC GRAVITY OF NATURAL GAS

0.58

0.60

0.62

0.64

Orifice

No.

Manifold

Pressure

High/Low

Orifice

No.

Manifold

Pressure

High/Low

Orifice

No.

Manifold

Pressure

High/Low

Orifice

No.

Manifold

Pressure

High/Low

USA

7001 to

8000

(2134

to

2438)

650

44

3.6/1.6

43

3.2/1.4

43

3.4/1.5

43

3.5/1.5

675

44

3.3/1.5

44

3.5/1.5

44

3.6/1.6

43

3.2/1.4

700

45

3.8/1.6

44

3.2/1.4

44

3.3/1.4

44

3.4/1.5

725

46

3.7/1.6

46

3.8/1.7

45

3.7/1.6

44

3.2/1.4

750

46

3.4/1.5

46

3.6/1.5

46

3.7/1.6

46

3.8/1.6

775

47

3.6/1.6

47

3.8/1.6

46

3.4/1.5

46

3.6/1.5

800

47

3.4/1.5

47

3.5/1.5

47

3.7/1.6

47

3.8/1.6

825

48

3.7/1.6

48

3.8/1.6

47

3.4/1.5

47

3.6/1.5

ALTITUDE

RANGE

FT. (M)

AVG. GAS

HEAT VALUE

AT ALTITUDE

(BTUH/CU FT.)

SPECIFIC GRAVITY OF NATURAL GAS

0.58

0.60

0.62

0.64

Orifice

No.

Manifold

Pressure

High/Low

Orifice

No.

Manifold

Pressure

High/Low

Orifice

No.

Manifold

Pressure

High/Low

Orifice

No.

Manifold

Pressure

High/Low

USA

8001 to

9000

(2438

to

2743)

625

44

3.3/1.5

44

3.5/1.5

44

3.6/1.6

43

3.2/1.4

650

45

3.7/1.6

44

3.2/1.4

44

3.3/1.4

44

3.4/1.5

675

46

3.6/1.6

46

3.8/1.6

45

3.7/1.6

45

3.8/1.7

700

47

3.8/1.7

46

3.5/1.5

46

3.6/1.6

46

3.7/1.6

725

47

3.6/1.6

47

3.7/1.6

47

3.8/1.7

46

3.5/1.5

750

48

3.8/1.7

47

3.5/1.5

47

3.6/1.6

47

3.7/1.6

775

48

3.6/1.5

48

3.7/1.6

48

3.8/1.7

47

3.5/1.5

USA

9001 to

10,000

2743 to

3048)

600

45

3.7/1.6

45

3.8/1.7

44

3.3/1.4

44

3.4/1.5

625

46

3.6/1.6

46

3.7/1.6

46

3.8/1.7

45

3.8/1.6

650

47

3.8/1.6

46

3.4/1.5

46

3.6/1.5

46

3.7/1.6

675

47

3.5/1.5

47

3.6/1.6

47

3.7/1.6

46

3.4/1.5

700

48

3.7/1.6

48

3.8/1.7

47

3.5/1.5

47

3.6/1.6

725

48

3.5/1.5

48

3.6/1.6

48

3.7/1.6

48

3.8/1.7

* Orifice numbers 43 are factory installed

315AA