315aa v, Fig. 58 -- troubleshooting guide – Bryant Gas Furance 315AAV User Manual

Page 56

Advertising
background image

56

Is AMBER

LED status light b

linking ON/OFF

slo

wly with a combinatio

n of shor

t and

long flashes?

Is AMBER LED status

light b

linking

rapidly without a pause?

Is AMBER LED status

light on?

Deter

mine status cod

e

.

The status

code is

a

2 digit number

with

t

he firs

t

digit

deter

m

ined

b

y the number of shor

t flashes and the

second digit b

y

the n

umber

of long flashes?

Go to section belo

w f

or the status cod

e

that w

as flashed

.

YES

NO

YES

T

o

recall pre

vious status codes

disconnect

the R ther

mostat connection, reset po

we

r,

and put setup s

witch SW1-1

in the ON

position.

The AMBER LED will flash the

status codes in the

order of o

ccurrence

.

Record status codes

until stat

us code #11

flashes (1 shor

t and 1 long

flash).

After status

code #11 flashes the status codes

will repeat.

Status codes are er

ased after 72 hours or

can be manually era

sed b

y

putting

setup

s

w

itch SW1-1 in the ON position and

jumper

ing R,

W/W1, and

Y/

Y2 simultaneousl

y

until status code #11 is flashed

.

When

done

put setup

s

w

itch SW1-1 in the OFF posi

tion.

Chec

k f

or correct line v

oltage po

lar

ity

.

If units are twinned,

chec

k f

or proper

lo

w-v

oltage (24V) transf

or

mer phasing.

W

a

s there a pre

vious status

code other

than #11

?

Is door s

witch closed

?

Is there 115V going to s

witch?

Replace door s

witch.

Replace transf

or

mer

.

Does the control respo

nd to

W/W1, W2,

Y1,

Y/Y2, and G

(24V) ther

mostat signals?

Replace fur

nace control.

NO

NO

NO

NO

Is 24V present at

W/W1,

W2, Y1, Y/Y2

or

G

ther

mostat ter

minals on the fur

nace control?

NO

YES

YES

Replace fur

nace con

trol.

Is there 24V at SEC-1 an

d SEC-2?

Is there 115V at L1

and L2?

YES

NO

YES

YES

NO

YES

NO

YES

Run system through a

lo

w-heat, high

-heat,

or cooling cycle to

chec

k operation.

Status

codes are erased after 72 hour

s or can be

manually erased b

y putting setup s

witch

SW1-1

in the ON po

sition and j

umper

ing R,

W/W1, and

Y/Y2

simultaneou

sly until status

code #11

is flashed

.

YES

NO

Close circuit bre

ak

er and go bac

k to ST

AR

T

.

Chec

k f

or continuity in

wire from circui

t

break

er to fur

nace

.

Is circuit break

er closed?

Is door s

witch closed

?

Chec

k room ther

mostat or

interconnecti

ng cab

le

.

NO

YES

YES

NO

The th

er

mostat is not compatib

le with the

fur

n

ace control.

Either install a ballast resistor

,

connect the Com24V

ther

mostat ter

minal to

the ther

mostat

, or replace the ther

mostat

.

Does the prob

lem repeat when using

a jumper wire?

Disconnect all

the ther

mostat wires fro

m the

fur

nace control.

ST

AR

T

A02108A

Fig. 58 -- Troubleshooting Guide

315AA