Warning, 315aa v – Bryant Gas Furance 315AAV User Manual

Page 9

Advertising
background image

9

1 SQ IN .

PER

4000

BTUH*

DUCTS

TO

O UTDOORS

1 SQ IN.
PER 4000
BTUH*

C

IRCULA

TING

AIR DUCTS

VENT
THR OUGH
R OOF

D

B

A

C

E

1 SQ IN.
PER 4000
BTUH*

DUCT

TO

OUTDOORS

CIRCULA TING AIR DUCT S

1 SQ IN.
PER 2000
BTUH*

1 SQ IN.
PER 2000
BTUH*

DUCT S

TO

OUTDOORS

12

MAX

12

MAX

12

MAX

12

MAX

12

MAX

OUTDOORS

1 SQ IN .

PER

4000

BTUH*

F

G

CLEARANCE IN FRONT

OF COMB

USTION AIR

OPENINGS SHALL BE

AT LEAST 3 IN

.

(305mm)

(305mm)

(305mm)

(305mm)

(305mm)

(76mm)

*Minimum dimensions of 3--- in. (76 mm).
NOTE: Use any of the following combinations of openings:

A & B C & D D & E F & G

A03174

Fig. 7 -- Air for Combustion, Ventilation, and Dilution for

Outdoors

S

Spaces having at least 50 cubic feet per 1,000 Btuh
may use the INDOOR COMBUSTION AIR,

STANDARD or KNOWN AIR INFILTRATION
METHOD.

Outdoor Combustion Air Method

1. Provide the space with sufficient air for proper combus-

tion, ventilation, and dilution of flue gases using perman-
ent horizontal or vertical duct(s) or opening(s) directly
communicating with the outdoors or spaces that freely

communicate with the outdoors.

2. Fig. 7 illustrates how to provide TWO OUTDOOR

OPENINGS, one inlet and one outlet combustion and
ventilation air opening, to the outdoors.

e. One opening MUST commence within 12 in. (300

mm) of the ceiling and the second opening MUST
commence within 12 in. (300 mm) of the floor.

f. Size openings and ducts per Fig. 7 and Table 2.

g. TWO HORIZONTAL DUCTS require 1 sq. in. (645

sq. mm) of free area per 2,000 Btuh (1,100 mm

2

/kW)

of combined input for all gas appliances in the space
per Fig. 7 and Table 2.

h. TWO OPENINGS OR VERTICAL DUCTS require 1

sq. in. (645 sq. mm) of free area per 4,000 Btuh (550

mm

2

/kW) for combined input of all gas appliances in

the space per Fig. 7 and Table 2.

3. ONE OUTDOOR OPENING requires:

a. 1 sq. in. (645 sq. mm) of free area per 3,000 Btuh

(734 mm

2

/kW) for combined input of all gas appli-

ances in the space per Table 2 and

b. Not less than the sum of the areas of all vent connect-

ors in the space.

CIRCULATING AIR

DUCTS

6" MIN

(FRONT)

Ü

CIRCULATING AIR DUCTS

VENT THROUGH ROOF

1 SQ IN.

PER 1000

BTUH* IN DOOR

OR

WALL

12" MAX

1 SQ IN.

PER 1000

BTUH* IN DOOR

OR

WALL

12" MA X

UNCONFINED

SPACE

INTERIOR

HEATED

SPACE

CLEARANCE IN FRONT OF COMBUSTION AIR

OPENINGS SHALL

BE A

T LEAST 3 IN.

(305mm)

(152mm)

(305mm)

* Minimum opening size is 100 sq in. (64516 sq. mm)with minimum dimensions

of 3 in. (76 mm)

† Minimum of 3 in. (76 mm) when type-B1 vent is used.

A03175

Fig. 8 -- Air for Combustion, Ventilation, and Dilution from

Indoors

The opening shall commence within 12 in. (300 mm) of the

ceiling. Appliances in the space shall have clearances of at least 1
in. (25 mm) from the sides and back and 6 in. (150 mm) from the

front. The opening shall directly communicate with the outdoors
or shall communicate through a vertical or horizontal duct to the

outdoors or spaces (crawl or attic) that freely communicate with
the outdoors.
Indoor Combustion AirE NFPA & AGA
Standard and Known--Air--Infiltration Rate Methods
Indoor air is permitted for combustion, ventilation, and dilution,

if the Standard or Known--Air--Infiltration Method is used.

CARBON MONOXIDE POISONING HAZARD
Failure to follow this warning could result in personal

injury or death.
Many homes require air to be supplied from outdoors

for furnace combustion, ventilation, and dilution of flue

gases.
The furnace combustion air supply must be provided in

accordance with this instruction manual.

!

WARNING

The Standard Method:

1. The space has no less volume than 50 cubic feet per 1,000

Btuh of the maximum input ratings for all gas appliances
installed in the space and

2. The air infiltration rate is not known to be less than 0.40

air changes per hour (ACH).

The Known Air Infiltration Rate Method shall be used, if the
infiltration rate is known to be:

1. Less than 0.40 ACH and
2. Equal to or greater than 0.10 ACH