Warning, Caution – Bryant Gas Furance 315AAV User Manual

Page 48

Advertising
background image

48

7. RELEASE BLOWER ACCESS DOOR SWITCH, reat-

tach wire to “R” terminal on furnace control board, replace

blower access door, and replace outer access door.

CARE AND MAINTENANCE

FIRE OR EXPLOSION HAZARD
Failure to follow this warning could result in personal

injury, death and/or property damage.
Never store anything on, near, or in contact with the

furnace, such as:

1. Spray or aerosol cans, rags, brooms, dust mops,

vacuum cleaners, or other cleaning tools.

2. Soap powders, bleaches, waxes or other cleaning

compounds, plastic or plastic containers, gasoline,

kerosene, cigarette lighter fluid, dry cleaning fluids,
or other volatile fluids.

3. Paint thinners and other painting compounds, paper

bags, or other paper products. Exposure to these
materials could lead to corrosion of the heat

exchangers.

!

WARNING

For continuing high performance and to minimize possible

furnace failure, periodic maintenance must be performed on this
furnace. Consult your local dealer about proper frequency of

maintenance and the availability of a maintenance contract.

ELECTRICAL SHOCK AND FIRE HAZARD
Failure to follow this warning could result in personal injury,

death, and/or property damage.
Turn off the gas and electrical supplies to the furnace and

install lockout tag before performing any maintenance or

service. Follow the operating instructions on the label

attached to the furnace.

!

WARNING

CARBON MONOXIDE POISONING AND FIRE

HAZARD
Failure to follow this warning could result in personal

injury, death and/or property damage.
Never operate furnace without a filter or with filter access

door removed.

!

WARNING

CUT HAZARD
Failure to follow this caution may result in personal injury.
Sheet metal parts may have sharp edges or burrs. Use care

and wear appropriate protective clothing, safety glasses and

gloves when handling parts, and servicing furnaces.

CAUTION

!

The minimum maintenance on this furnace is as follows:

1. Check and clean air filter each month or more frequently if

required. Replace if torn.

2. Check blower motor and wheel for cleanliness each heat-

ing and cooling season. Clean as necessary.

3. Check electrical connections for tightness and controls for

proper operation each heating season. Service as neces-

sary.

4. Inspect burner compartment before each heating season

for rust, corrosion, soot or excessive dust. If necessary,

have furnace and burner serviced by a qualified service
agency.

5. Inspect the vent pipe/vent system before each heating sea-

son for rust, corrosion, water leakage, sagging pipes or
broken fittings. Have vent pipes/vent system serviced by a

qualified service agency.

6. Inspect any accessories attached to the furnace such as a

humidifier or electronic air cleaner. Perform any service or
maintenance to the accessories as recommended in the ac-
cessory instructions.

Cleaning and/or Replacing Air Filter
The air filter arrangement will vary depending on the application.
NOTE: If the filter has an airflow direction arrow, the arrow
must point towards the blower.

CUT HAZARD
Failure to follow this caution may result in personal injury.
Sheet metal parts may have sharp edges or burrs. Use care

and wear appropriate protective clothing, safety glasses and

gloves when handling parts, and servicing furnaces.

CAUTION

!

Media cabinet filter procedures:

1. Turn off electrical supply to furnace before removing filter

access door.

2. Remove filter cabinet door.
3. Slide filter out of cabinet.
4. If equipped with permanent, washable 3/4--in. (19 mm)

filter, clean filter by spraying cold tap water through filter

in opposite direction of airflow. Rinse filter and let dry.
Oiling or coating of the filter is not recommended. See
Table 15 for size information.

5. If equipped with factory--specified disposable media filter,

replace only with media filter having the same part num-

ber and size. For expandable replacement media, refer to
the instructions included with the replacement media.

6. Slide filter into cabinet.
7. Replace filter cabinet door.
8. Turn on electrical supply to furnace.

Blower Motor and Wheel

ELECTRICAL SHOCK HAZARD
Failure to follow this warning could result in personal

injury or death.
Blower access door switch opens 115--v power to control.

No component operation can occur unless switch is closed.

Caution must be taken when manually closing this switch

for service purposes.

!

WARNING

NOTE: The blower wheel should not be dropped or bent as
balance will be affected.
The following steps should be performed by a qualified

service agency.
To ensure long life and high efficiency, clean accumulated dirt
and grease from blower wheel and motor annually.

315AA

V

Advertising