5.4 Pumps

Depending on the type, a single-flow, double-flow or triple-flow pump is built into LUKAS

hydraulic units.

Single-flow pump

1 pump capacity

Double-flow pump

2 pump capacities

Triple-flow pump

3 pump capacities

The pumps used are always equipped with two pressure levels for each pump capacity, one

low-pressure and one high-pressure level.

Low-pressure level (ND) = up to 16 MPa*

High-pressure level (HD) = up to 70 MPa*

The changeover from low pressure to high pressure is carried out automatically in the pump.

The maximum pressure is limited by a pressure limiting valve.

WARNING / DANGER / CAUTION!

For reasons of safety, the pressure set on this valve

must not be adjusted

(without direct authorisation from LUKAS)!

5.3.3 Control valve "automatic operation (ISV valve)"

This valve enables the connection of two pressure hoses and two return hoses. The

patented LUKAS ISV valve provides one device at each connecting block with pressure

without a manual switching procedure. Changeover between the two pressure hoses is

automatic. With this control valve, the first driven and pressure-operated connected device

is always provided with hydraulic fluid. The second connected device, on the other hand, is

automatically disconnected from fluid supply.

5.3.4 Control valve "simultaneous operation"

This valve enables the connection of two pressure hoses and two return hoses. It has two

switching options, each of which controls the pressure application of the pressure hose

that is marked accordingly. This means

two devices can be supplied with pressure

simultaneously and independently of one another. Without impairing the work output, it

enables work with two devices simultaneously and independently of one another.

5.3.5 Control valve "triple-flow operation"

This valve enables the connection of three pressure hoses and three return hoses. It has

three switching options, each of which controls the pressure application of the pressure hose

that is marked accordingly. This means

three devices can be supplied with pressure

simultaneously and independently of one another. Without impairing the work output, it

enables work with three devices simultaneously and independently of one another.

*) 1 MPa = 10 bar)