Lukas P 640 TG User Manual

Page 26

Advertising
background image

26

9.3.4 Control valve "simultaneous operation"

Two levers are fitted on this valve. Each lever is assigned to one pressure port. The pressure

application of the relevant pressure hose is controlled by turning the relevant lever.

There are 2 switching stages for each lever:

0 = circulation at static pressure (no pressure supplied to the hydraulic hose)

1 = pressure supply to the pressure hose

9.3.5 Control valve "triple-flow operation"

Three levers are fitted on this valve. Each lever is assigned to one pressure port. The pressure

application of the relevant pressure hose is controlled by turning the relevant lever.

There are 2 switching stages for each lever:

0 = circulation at static pressure (no pressure supplied to the hydraulic hose)

1 = pressure supply to the pressure hose

Case 3: Two hose pairs and one rescue device are connected (at connection A):

If two hose pairs are connected and there is only one rescue device at the hose pair of

connection "A", the following instructions are important:

1. The control lever for switch positions must be in position "A".

2. The hydraulic fluid supply of the connected rescue equipment and switching to circulation

at static pressure take place by switching the control lever for the outlet valve. ("1" = fluid

supply; "0" = circulation at static pressure)

Case 4: Two hose pairs (with quick-disconnect couplings) and one rescue device are

connected (at connection B):

If two hose pairs are connected and a rescue device is only connected at the hose pair of

connection "B", the device works neither in switch position "A" nor in switch position "A+B".

The second hose pair at connection A without a connected rescue device indicates to the

valve that a device is connected at connection A that has to be supplied with maximum

operating pressure. This switches off connection B, which is no longer supplied with hydraulic

fluid.

To exclude this possibility, you should either connect a second rescue device or join the

supply and return hoses of the connection that is not used (short-circuiting).

Case 5: Two hose pairs (with mono-couplings) and one rescue device connected (at

connection B):

If two hose pairs are connected and a rescue device is only connected at the hose pair

of connection "B", the device only works in switch position "A+B". This is made possible

by the female mono-coupling halve, which enables an internal fluid circulation when not

connected.

Advertising