12.2 Preventive service

12.2.1 Care regulations

The exterior of the equipment is to be cleaned from time to time in order to protect it from

external corrosion. Oil is to be applied to the metallic surfaces.

12.2.2 Function and load test

If there is any doubt regarding the safety or reliability of the equipment, a function and load

test must also be performed.

LUKAS offers appropriate test equipment.

12.2.3 Replacing the hydraulic fluid

- After approx. 200 deployments, but after three years at the latest, replace the hydraulic

fluid

- The fluid should be replaced when it is warmed up.

- The motor must be switched off!

- The old hydraulic fluid must be disposed of properly.
Procedure:

1. Place the collection basin underneath the drain plug of the unit.

2. Undo the venting and drain plug of the unit and let the fluid flow into the collection basin.

This enables easy cleaning of the hydraulic unit.