Trouble

Cause

Solution

Fluid leaks from the

hydraulic fluid reservoir

(especially from the filler

screw)

Return of the hydraulic

fluid from the rescue

device exceeds the

reservoir’s maximum

quantity when filled.

Reduce the level in the

hydraulic fluid reservoir to

the mark on the dipstick or

inspection glass

Defective seal

Have repaired by

authorised dealer or

directly by LUKAS

Leaking fluid between

engine and flange bearing

Radial shaft seal on the

drive shaft is defective

Have repaired by

authorised dealer or

directly by LUKAS

Hydraulic fluid milky and

cloudy

Water / condensation in

the system

Immediately replace

hydraulic fluid

With mono-coupling-

system: hose assembly

cannot be coupled

Pressure too high (e.g.

caused by excessive

ambient temperature)

Switch valve block to

circulation at static

pressure
For the ISV valve: Have

repaired by authorised

dealer or directly by

LUKAS

Coupling defective

Coupling needs to be

replaced immediately

With mono-coupling-

system: It is frequently not

possible to couple hose

assemblies

Hydraulic fluid not adapted

to the application situation

Hydraulic fluid must be

replaced (see chapter

“Recommended hydraulic

fluids”)

Coupling defective

Coupling needs to be

replaced immediately

With quick-disconnect

coupling system: hose

assembly cannot be

coupled

Pressurised

Switch valve block to

circulation at static

pressure
For the ISV valve: Have

repaired by authorised

dealer or directly by

LUKAS

Coupling defective

Coupling needs to be

replaced immediately

With mono-coupling-

system: Leak in the

couplings

Coupling defective

Coupling needs to be

replaced immediately