Lukas P 640 TG User Manual

Page 36

Advertising
background image

36

CAUTION with (quick-disconnect-system)!

As the case may be, make sure that reservoir port 'T' or 'T1' of the unit is always

equipped with a female quick-disconnect coupling.

On the other hand, the supply ports must be equipped with a male quick-

disconnect coupling.

12.3.6 Replacing the valve blocks

Replace the valve blocks if they are leaky or defective and direct repair of the valve block by

a dealer or LUKAS is no longer possible. The valve block may only be replaced when the

hydraulic unit is switched off. Electric motors must be disconnected from the power supply.

Replacing the valve blocks of the 640 units:

1. Disconnect all hoses from the valve block.

2. Loosen the fastening screws of the hydraulic

fluid reservoir and remove the fluid filler

caps.

3. Remove the hydraulic fluid reservoir.

Please ensure that the hydraulic fluid does not

become contaminated, or replace the hydraulic fluid.

4. Loosen the union nut on the piping of the

valve block and the fastening screws of the

valve block.

5. Remove this and the seal underneath it.

6. Remove the connection nipple for the piping and the

return pipe from the valve block.

Advertising