Maintenance and service 11 – Lukas P 640 TG User Manual

Page 28

Advertising
background image

28

Maintenance and service

11.

The hydraulic units are subject to very high mechanical loads. A visual inspection is therefore

to be carried out after every use: however, at least one visual inspection is to be carried out

every six months.

This reveals wear and tear in good time; punctual replacement of these wearing parts

prevents damage to the equipment. Also check regularly that all the securing screws are

tightened (if applicable, comply with prescribed tightening torques)

Every 3 years or when there might be doubts regarding the safety or reliability of the unit, an

additional function check is to be carried out (in this connection, comply with the applicable

national and international regulations with regard to the maintenance intervals of rescue

equipment). In the Federal Republic of Germany, regular safety inspections according to the

regulations of the

Gesetzliche Unfallversicherung (GUV; 'statutory accident insurance') are

mandatory.

CAUTION!

Clean off any dirt before checking the equipment!

WARNING / DANGER / CAUTION!

In order to carry out maintenance and repair work, tools appropriate for the job

and personal protection equipment obligatory (including protective covers).

LUKAS offers a suitable test kit for the function test of the hydraulic units.

(For specific details, please consult the LUKAS range of accessories or contact your

LUKAS dealer).

11.1 Recommended testing periods

11.1.1 Visual inspection

11.1.2 Function test

A visual inspection must be made after each use / latest once a year.

Operating time per day Function test
up to 1 hour

once per year

up to 8 hours

once per 3 months

up to 24 hours

once per month

Beyond these testing periods, a function test should be accomplished, if the aggregate

makes suspicious noises, or there is a reasonable suspicion of an internal damage of the

aggregate.

If the noises or suspicious factors named above should occur several times during one

month or the hydraulic unit does not reach the nominal pressure (75% of the maximum

pressure) during the functional test, you will have to contact the LUKAS customer service

immediately. You will find the contact information in the chapter 'Troubleshooting'.

Advertising