43

If it is not possible to rectify the malfunctions, inform an authorised LUKAS dealer or the

LUKAS Customer Service department immediately!

The address for the LUKAS Customer Service department is:

LUKAS

Hydraulik GmbH

Weinstraße 39, D-91058 Erlangen

Postfach 2560, D-91013 Erlangen

Tel.: (+49) 09131 / 698 - 348

Fax.: (+49) 09131 / 698 - 353

REMARK:

Before shipping units of the type P620x, the locking screw for transport protection

must be bolted onto the unit once again. (Reverse order as shown in the chapter

"Set-up and start-up").

Trouble

Cause

Solution

With quick-disconnect

coupling system: Leak in

the coupling (male)

Safety valve reacted

After pressure release,

there is no more leakage.

Coupling (male) defective Coupling (male) needs to

be replaced immediately

With quick-disconnect

coupling system: Leak in

the coupling (female)

Female coupling defective Female coupling needs to

be replaced immediately

Hydraulic fluid leak on the

hoses or the connections

Leak, possible damage

Replace hoses

Damage on the surface of

the hydraulic hoses

Mechanical damage or

contact with aggressive

agents

Replace hoses