Lukas P 640 TG User Manual

Page 41

Advertising
background image

41

Trouble

Cause

Solution

The connected rescue

equipment does not move

on activation of the valve,

or moves only very slowly

or unevenly.

Air in the hydraulic supply Vent the hydraulic system

Pressure relief on the unit

is still active (circulation at

static pressure)

Check the switching

positions of the valve

lever(s) and, if necessary,

reset (as far as the final

position)
For the ISV valve: Have

repaired by authorised

dealer or directly by

LUKAS

Connecting block defective Replace connecting block

Have repaired by

authorised dealer or

directly by LUKAS

Defective pump unit

Have repaired by

authorised dealer or

directly by LUKAS

Mono-coupling (female)

defective

Replace mono-coupling

(female)

Connected rescue device

does not reach its final

position

Insufficient fluid in the

hydraulic reservoir

Top up hydraulic fluid to

the maximum filling level

Caution! Before

topping up the rescue

equipment, return to the

base position!

Usable hydraulic fluid

volume of the unit is

insufficient

Use a different rescue

device with a usable

quantity below the

maximum usable quantity

of the unit

Connected rescue device

does not reach its specific

performance data

Maximum permitted

operating pressure of the

pump is not reached

Have the pressure limiting

valve reset or repaired

by authorised dealer or

directly by LUKAS

Pump or connecting block

defective

Have repaired by

authorised dealer or

directly by LUKAS

Advertising