SECTION 7 - GENERAL SPECIFICATIONS & OPERATOR MAINTENANCE

3121261

– JLG Lift –

7-15

4.

A. Wheel Drive Hub - Bonfiglioli

Lube Point(s) - Level/Fill Plug
Capacity - 2.1 quarts (2 liters) ± 10%
Lube - EPGL
Interval - Change after first 150 hours then every 1200 hours of

operation

Comments - Place Fill port at 12 o’clock position and Check

port at 8 o’clock position. Pour lubricant into fill port until it
just starts to flow out of check port.

B: Wheel Drive Hub - Reggiana Riduttori

Lube Point(s) - Level/Fill Plug
Capacity - 0.5 quarts (0.5 liters) ± 10%
Lube - EPGL
Interval - Change after first 150 hours then every 1200 hours of

operation

Comments - Place Fill port at 12 o’clock position and Check

port at 3 o’clock position. Pour lubricant into fill port until it
just starts to flow out of check port.