SECTION 7 - GENERAL SPECIFICATIONS & OPERATOR MAINTENANCE
3121261
– JLG Lift –
7-15
4.
A. Wheel Drive Hub - Bonfiglioli
Lube Point(s) - Level/Fill Plug
Capacity - 2.1 quarts (2 liters) ± 10%
Lube - EPGL
Interval - Change after first 150 hours then every 1200 hours of
operation
Comments - Place Fill port at 12 o’clock position and Check
port at 8 o’clock position. Pour lubricant into fill port until it
just starts to flow out of check port.
B: Wheel Drive Hub - Reggiana Riduttori
Lube Point(s) - Level/Fill Plug
Capacity - 0.5 quarts (0.5 liters) ± 10%
Lube - EPGL
Interval - Change after first 150 hours then every 1200 hours of
operation
Comments - Place Fill port at 12 o’clock position and Check
port at 3 o’clock position. Pour lubricant into fill port until it
just starts to flow out of check port.