SECTION 3 - MACHINE CONTROLS AND INDICATORS

3121261

– JLG Lift –

3-17

Platform Control Indicator Panel

(See Figure 3-4., Platform Control Indicator Panel)

1.

Level System Fault Indicator

Indicates a fault in the electronic leveling
system. The fault indicator will flash and
an alarm sound. All functions will default
to creep if the boom is out of transport
mode.

IF THE LEVEL SYSTEM FAULT INDICATOR IS ILLUMINATED, SHUT DOWN THE
MACHINE, RESET THE EMERGENCY STOP, AND RESTART THE MACHINE. IF THE FAULT
PERSISTS, RETURN THE PLATFORM TO THE STOWED POSITION, USING MANUAL LEV-
ELING AS REQUIRED, AND HAVE LEVELING SYSTEM REPAIRED.

2.

AC Generator (If Equipped)

Indicates the generator is in operation.

3.

Platform Overload Indicator (If Equipped)

Indicates the platform has been over-
loaded.

4.

Platform Capacity Indicator

Indicates the maximum platform capacity
selected for the platform.

One of the capacity lights should be on at
all times. Both lights will flash and an
alarm will sound if the platform is out of
the operating envelope for the selected
capacity.