SECTION 3 - MACHINE CONTROLS, INDICATORS AND OPERATION

3121230

– JLG Lift –

3-13

4

3

Tilt Condition
(Platform Elevated)
DRIVE and Lift UP Disabled

Lower the Platform and Drive off
the Tilt Condition

6

8

Drive Motor Brush Wear Warn-
ing ( 25 hrs. of DRIVE operation
remaining to a 10 sec. shut
down mode)

Drive Motor Brushes Require
Service Replacement -
(See Section 5.5 on page 5-20
for further Instructions)

13

6

Traction Module
Over Temperature
(DRIVE Disabled)

Allow Drive System Traction
Module to Cool Before
Operating

17

7

Ground Control Module
Over Temperature
(Machine Stopped)

Allow Ground Control
Module to Cool Before
Operating

32

7

Pump Motor Over Current
(LIFT UP Disabled)

Platform Load Over Capacity

33

2

Both PHP Bars UP
DRIVE and Lift UP Disabled

Check for Object Blocking Both
the Left and Right PHP Bars

Table 3-2. LCD Display - Operation Fault Conditions (Continued)

FAULT

CODE

PLATFORM

LEDS

FLASHING

LCD SYMBOL SCREEN

LCD TEXT SCREEN

FAULT DESCRIPTION/
MACHINE CONDITION

LOOK FOR THIS

04

04

00000.0

13

13

00000.0

17

17

00000.0

32

32

00000.0

33

33

00000.0