LED Indicator

RED LED indicates that the battery is in the initial charging phase.
YELLOW LED indicates that the battery has reached 80% of recharge.
GREEN LED, staggered with red flashings, indicates that battery rea‑
ched the balance/maintenance phase.

Further information are available in the description of the Charge
Curve.
Example: RED LED on with short shutdowns indicates a constant vol‑
tage phase.

Warnings (two‑tone beep)
A two‑tone beep and flashing LED indicates that an alarm situation occurred.

In case of alarm the battery charger stops supplying power.

BOOM LIFT MODELS X20JPLUS

JLG

106

X20JPR0020413

0

7

2

6

4

8

0

0

A

vuoto

Condition

Type of Warning

Description (Action)

Beep + flashing RED

Battery presence

Battery disconnected or not compliant
(Check the connection and the nominal
voltage).

Beep + flashing YELLOW

Thermal probe

Thermal probe disconnected during
recharge or out of functioning range
(Check the connection of the probe and
gauge the temperature of the battery).

Beep + flashing GREEN

Timeout

Phase 1 and/or phase 2 longer than the
maximum permitted (check the capacity
of the battery).

Beep + flashing RED‑YEL‑
LOW

Battery Power

Loss of control of output current
(Failure of control logic).

Beep + flashing
RED‑GREEN

Battery voltage

Loss of control of output voltage (Bat‑
tery disconnected or failure of control
logic).

Beep + flashing
YELLOW‑GREEN

Selection

An unused configuration has been selec‑
ted (Check the position of the selector).

Beep + flashing
RED‑YELLOW‑GREEN

Thermal

Semiconductors overheating
(Check the functioning of the fan).

Advertising