JLG X20J Plus Operator Manual User Manual

Page 111

Advertising
background image

107

TECHNICAL SPECIFICATIONS
T=25°C unless otherwise specified.

Before use, carefully read the instruction booklet.
Make sure that the charge curve selected is suitable for the type of battery being rechar‑
ged.

BOOM LIFT MODELS X20JPLUS

JLG

X20JPR0020413

ATTENZIONE

Description

Symbol

Test conditions

Value and/or

Range

Unit

Single‑phase power supply voltage

Vin

230 ± 10%

Veff

Frequency

f

50 ÷ 60

Hz

Maximum current drawn per phase

Ifmax

P = Pmax

20

Aeff

Initial current peak

Vin=230Veff

< 1,35

A

Power factor

cosφ

P = Pmax

0,68

Minimum power consumption

Pinmin

End of charge

< 5

W

Maximum power consumption

Pinmax

P = Pmax

3

kW

Output current

I

35

A

Output voltage

U

72

V

Maximum power supplied

Pmax

U = U1, I = I1

2550

W

Operating temperature range

ΔT

da ‑20 a +50

°C

Maximum relative humidity

RH

90%

Switching frequency

fc

30 ± 5%

kHz

Efficiency

η

Every operating con‑
dition

90%

Maximum dimensions

a×b×c

Without connection
cables

430Ч220Ч95

mm

DANGER