7.25.1 CHECKING THE ELECTROLYTE LEVEL THERMIC VERSION

The battery does not need to be topped up.
However, if the electrolyte, with the machine on a level
surface, is below the minimum allowed level (MIN.), it is
possible to top up by removing the lid “A” and adding
distilled water without exceeding the maximum level
(MAX.). Only for no AGM technology battery (Absorbed
Glass Mat).

If the machine is going to remain unused for more than one month, it is advisable to insulate
the battery:

Disconnect the battery terminals, always starting from the negative pole (‑).

Reconnect the cables, always starting from the positive pole (+).

7.25.2 RECHARGING THE BATTERY THERMIC VERSION

The battery must be recharged in well ventilated places, away from naked flames and
possible sources of sparks.

Do not disconnect the cables with the engine running.

The machine is equipped with an internal battery charger. To recharge the battery, con‑
nect the machine to the mains power supply and press the corresponding switch
(photo).

Before connecting the machine to the mains power supply.

Make sure that the battery cutout switch is not disconnected.