Alternatively, it is possible to recharge the battery by proceeding as follows:
1)

Disconnect the terminals of the machine’s electrical system from the battery poles.

2)

Remove the lid “A” (Figure 1).

3)

Connect the cables of the battery charger to the battery poles and switch the recharger
on.

4)

Once the charge has been completed, switch the device off before disconnecting it from
the battery.

5)

Fasten the terminals to the battery poles, then protect them with a layer of pure vaseline
or another suitable substance.

6)

Close the battery with the lid “A” (Figure 1).

The charging voltage must never exceed 14.7 Volts and the charge intensity must always
be limited to 0.2% of the value indicated on the lid.

7.25.3 REPLACING THE BATTERY THERMIC VERSION

‑ Do not disconnect the cables with the engine running.
‑ Before disconnecting the cables, turn the engine key to position OFF.
‑ Disconnect the battery terminals, always starting from the negative pole (‑).
‑ Reconnect the cables, always starting from the positive pole (+).

When the battery cannot accumulate electric energy any longer, replace it with a new one
having the same characteristics.
See the specifications table on the battery.

7.25.4 BATTERY DISPOSAL

The batteries must be disposed of in compliance with the specific regulations in force.