Lift Cabin Audio Unit

– Compact

2.3

40

Electric Installation (Earlier HW)

Caution

Be sure to connect the wires before wall mounting. The connectors are
separable – remove them, connect the wires, tighten the screws and
replace the connectors.

Connectors

Bus connector

CANCEL connector (optional)

in contact-control position

in voltage-control position

Electric Installation (Later HW)

Terminals

Telephone line / LN bus

Refer to ST or LN User Manual

ALARM

terminals

DC = voltage
control *)

5 – 24Vdc, any polarity

Emergency call
activation

N.O. = N/O contact Normally open contact
N.C. = N/C contact Normally closed contact

WARNING! If unused, the
contact should not be opened!

CANCEL

terminal

voltage control *)

5 – 24Vdc, any polarity **)

Emergency call
deactivation upon
door opening

contact control

any contact **)

*) For safety reasons, these terminals are electrically isolated from the telephone line.

**) You need not do anything to activate ALARM if you keep the factory settings. For
deactivation, voltage application or contact closing is necessary. To change the
settings use parameter 916 for ST and the rotary switch for LN.

Figure 2.12
Connectors of
Lift Cabin
Audio Unit –
Compact
(Earlier HW)