Technical Parameters

6.1

88

6.1 Technical Parameters

Telephone Parameters

Parameter

Value

Conditions

Minimum line current

15 mA

off-hook

Minimum line voltage

22 V

on-hook

Off-hook DC voltage drop

< 8 V
< 16 V

I = 25 mA

I = 50 mA

Off-hook resistance

>1MΩ

U = 25..100
V

Off-hook impedance

220 Ω + 820
Ω paral. 115
nF

20 to 60 mA

Return loss

> 14 dB

20 to 60 mA

Bandwidth

300 to 3500
Hz

20 to 60 mA

Ringing impedance

> 2 kΩ
C = 1 μF

25 to 50 Hz

Ringing detector sensitivity

10 to 20 V

25 to 50 Hz

Pulse dialling

40 / 60 ms

DTMF dialling level

6 a 8 dB ± 2
dB

20 to 60 mA

Dial-tone detector sensitivity

approx. 43
dB

Overvoltage protection- between
A, B

1000 V

8 / 20 μs

Notes

All the product parameters comply with TBR-21 on condition that the
product is to be operated as a single line terminal, i.e. no parallel
connection with any other equipment is allowed.

Line interference and noise picked up by the LN microphone are relevant
factors.

Advertising