Parameter Chart (FW v. 1.8.0)

3.2

63

Par.
No.

Parameter Name Range

Default

Note

977

Checking call

sequence

Up to 8

messages
(each has

2-digit ID)

blank

(=2829

1612)

22 = "Wait please, connection is being
established"
23 = "This is an emergency call"
24 = "Press 1 for connection with the lift cabin"
25 = " Press 1 for connection with the lift"
26 = Outgoing DISA ("Press 1 for connection
with the lift cabin. Press 2 to mute the
message. Press 3 to repeat the message. Press
5 to terminate the call.")
27 = "Connection confirmed"
28 = "This is a checking call"
29 = "This is communicator ..."

Cautions:

1) User messages

#1 to #10 are

recorded into the CU with the aid of
Service Tools

2) "" = voice message
3) DTMF sequence (2N protocol)


Format: *X*Y
Y*ID(par.974)*checksum#
X=1 - Alarm, 2 – Checking call
YY=00 – Checking call, SA – shaft +
audio unit ID (e.g. SA=11 means shaft
1 and cabin audio unit)

978

Sequence of
messages upon call
confirmation by
button 1

Up to 8

messages
(each has

2-digit ID)

blank

(=27)

979

Sequence of
messages for
dispatching upon
pressing of button 3

Up to 8

messages
(each has

2-digit ID)

blank

(=1612
171318

14)

981

Checking call

0 – 4

0

0 = off
1 = checking call in 1 minute
2 = on, first call in 2 hours
3 = on, first call in full period time

4 = on, checking call according to parameter
986 (Days in week)

CAUTION! Each of the values switches on

periodic checking calls, the period is the same,

only the first call time is different.

982

Checking call interval

hhmmhhm

m

00002359

Allows to force a checking call e.g. at night
(lower fee).

983

Checking call period

0 – 100

days

3 days

0 = OFF (however, setting parameter 981 to 0
has the same effect).

984

Time adjustment

hhmmss

or hhmm

blank

Necessary if the Checking call interval is used

(can only be set via the voice menu;
synchronisation with the PC time is made via
the Service Tool).

985

Date adjustment

yymmdd

blank

Configure when parameter 986 is set to Days in
week (upon a date change, the test call date is
rescheduled according to the new date)

(can only be set via the voice menu;
synchronisation with the PC time is made via