Dispatching Centre Instructions

4.2

72

Setting Machine Room Audio Unit Number

Enter # before the lift number to set the machine room number.

For example, 011 - #8 means that calling to lift 8 machine room audio unit is set in
ALARM button memory 1.

Setting options:

1. Service Tools – enter # and lift number into parameters

011-016.

2. Set the lift number into the button memory (011-016) in

the programming menu, select parameter 017 (refer to
the table of parameters) and enter the required character
(#) into the appropriate button memory.

Caution

The dispatching-intercom audio unit is set as lift 8 type machine
room by factory default.

You can set alarm-intercom for lifts 1-7 too. All you have to do is change
the lift address (jumper) and set another number into the ALARM button
memory.

The dispatching centre audio unit must be of the machine room
type and set as the machine room.
If it is set otherwise (as a shaft,
cabin or roof), no call to the unit will be successful.

Note

It is possible to combine calling to the machine room (dispatching) audio
unit with calling via the PSTN.

To set up a checking call to a machine room audio unit, you can set the
number as described in the Alarm – Intercom subsection above.