Parameter Chart (FW v. 1.8.0)

3.2

60

Par.
No.

Parameter Name Range

Default

Note

076

Checking call
memory 6

up to 16

digits 0 - 9

blank

077

Adding of a special

symbol *, # and

“delay”

078

Count of automatic
dialling cycles for
checking call

0 - 9

3

079

Automatic dialling
type
for checking call

0 - 3

1

see parameter 019

906

Delay after digit
dialling

cannot be

changed

100ms

The parameter cannot be changed. It gives the

delay between the digit dialling and voice

message start.

909

Timeout for dialling
tone detection

1000 –

9999 ms

5000 ms

LN waits for the dialling or continuous tone for

this period of time. If it fails, the line is

defective.

911

Count of rings before
incoming call
answering

1 - 9

2

Defines the moment of picking up (for incoming

calls).

912

Max. call duration

10 – 1000

s

120 s

Call can be prolonged by command.

913

Timeout for call
confirmation

10 – 1000

s

60 s

LN waits for confirmation for this period of time

(outgoing call, automatic dialling with come

confirmation enabled).

If it fails, LN hangs sup and proceeds to the

next number. Measured from the dialling end.

914

Delayed call

0 – 1000 s

0 s

Applicable only if the CANCEL input is used

(913610E unit only).

915

Max. TRIPHONY
duration

10 – 9999

s

7200 s

917

On-hook time
between calls

500 –

9999 ms

5000 ms

918

Max. time of
telephone line test

1 – 20 s

5 s

A line test (dialtone test) is made every 11
minutes. If the dialtone is missing in three
subsequent tests, the lift gets blocked. When
the line is recovered, the lift gets unblocked
automatically.

920

Call confirmation
command

cannot be

changed

1

Mutes the message too.

921

Message muting
command

cannot be

changed

2

Advertising