5 log files – 2N BRI Lite/Enterprise v1.2 User Manual

Page 87

Advertising
background image

87

2N TELEKOMUNIKACE a.s., www.2n.cz

®

6.5 LOG Files

Type

Text

Description

POWER

[Power on]

System switched on

[Power off]

System switched off

[Warm boot]

Restart of system, unknown cause

[Watchdog]

Restart of system by watchdog

[BKPT code]

CPU error: break code detected

[Stack error]

CPU error: stock integrity failure

[Divided by
zero]

CPU error: dividing by zero

[RETI code]

CPU error: illegal using of instruction reti

[NMI intr]

CPU error: wrong interrupt

[VOID intr]

CPU error: wrong interrupt

[Upgrade reset] Start of upgrade firmware procedure

[Software
reset]

Reset by AT commands (at&fres…)

INIT

Eeprom

Initialisation of eeprom (configuration)

Flash

Initialization of flash memory (firmware)

HW–ERR

(##…address of chip, RD…read value/WR…expected
value)

Duart
#####,RD/WR

Error in initialization of serial controller on GSM board

SYSERR

User stack
error!

SW error: stock integrity failure

BRDIN

#08 TYP STS

the board inserted (number of gsm board, type, status)

BRDOUT #08 TYP STS

the board disconnected

BRDRES

#08 TYP STS

Reset the board by AT command

ALL GSM
RESET CMD

Reset of all GSM boards by AT command

SYSTEM RESET
CMD

Reset of system by command at&bsys

L1–ERR

(reserved)

L2–ERR

Error of 2. ISDN layer by Q.921

A: unsol.RX(F)

Received packed RR,RNR,REJ with unexpected bit F=1

B: unsol.DM(F)

Received packed DM with unexpected bit F=1

C: unsol.UA(F)

Received packed UA with unexpected bit F=1

D: unsol.UA(–)

Received packed UA with unexpected bit F=0

E: unsol.DM(–)

Received packed DM with unexpected bit F=0

F: peer re–est

Received packed SABME in status OKEST