Configure se5001a as tcp client – Atop Technology SE5001A User manual User Manual

Page 22

Advertising
background image

User Manual Version 1.0

SE5001A Serial Device Server

20

3.2.6. Configure SE5001A as TCP Client

Figure 3.8 Link Mode: TCP Client Setup

 Type 2

in the “Input choice(1~5) and enter:“

Input destination IP in the “Please input Destination IP:”

Input destination port in the “Please input Destination port:”

 Select TCP connection behavior: 1 for connect always, 2 for connect on serial data

If 2 is selected, console will prompt for additional configurations.

Input idle time to disconnect in the “Please input idle time to disconnect(0sec , 1~255):” (Input 0 to
disable; Input 2 to disconnect TCP connection after 2 seconds of serial Inactivity)

Input error retrying time in “Please input waiting time for error retrying(0 minute,1~255):” (Input 0
to disable; Input 2 to try to connect to a TCP Server every 2 minutes)

Input idle time in “Please input idle time to send TCP alive packet(x*10sec):”(Input 2 to the send TCP
keep alive packet every 20 seconds)