Atop Technology SE5001A User manual User Manual

Page 32

Advertising
background image

User Manual Version 1.0

SE5001A Serial Device Server

30

Enable SNMP and Alert Events by

checking “Enable(Figure 3.20). Fill in SNMP information in the fields under the

SNMP header. Enable different Alert Events to send these events to a SNMP Trap Server.

Cold/Warm Start: Triggers when the device is rebooted from the application level or physical level.

Link Down: Triggers when the TCP connection of the designated COM port is closed

Link Up: Triggers when the TCP connection of the designated COM port is established

Authentication Failure: Triggers when the username/password entered in the Telnet console or the WebUI is
incorrect.

Figure 3.20 SNMP Setup

After all the settings are entered, please click on the

“Save Configuration” button to save the changes. Note that

the settings would become active only after SE5001A is restarted.

Advertising