User manual Version 1.3

4-Port DIN-Rail Serial Device Server SE5404D

Copyright © 2011 Atop Technologies, Inc.

All rights reserved. Designed in Taiwan.

- 40 -

Figure 3.31 UDP in Link mode

Note: UDP mode doesn’t support Virtual COM mode yet

3.4.5 Serial Settings

This filed can configure serial parameters for Serial Server. Here one may configure Serial parameters,
include UART Mode, baud rate, parity, data bit and type of flow control you wanted

Configuring UART Mode: RS-232 or RS-485 or RS-422
Baud rate: 300 / 600 / 1200 / 2400 / 4800 / 9600 / 19200 / 38400 / 57600 / 115200 / 230400 / 460800 /

500000 / 576000 / 921600

Parity: None or Odd or Even or Mark or Space
Data bits: 7 or 8
Stop bits: 1 or 2
Flow control: None or Xon/Xoff or Hardware (RTS/CTS)
Disable FIFO: No/Yes. For serial devices that are very sensitive to the amount of data that they receive,

FIFO should be disabled. For regular applications, we recommend to enable FIFO (default) to achieve
optimal performance.

If you check “Apply to all serial ports”, it will configure all of the serial ports.