Basic Operation

Switching

There are [3] methods by which you can control the ASW-

WP switching functions:

1. Auto – By placing a jumper, between the “Auto” and

“Gnd” terminals on the back of the ASW-WP, the unit

will switch inputs by sensing video signal.

a. The ASW-WP will switch automatically to the

“last in” connected input. For example: if you

have a VGA signal displayed, and then

connect an HDMI source, the unit will switch

to the HDMI input. If you then remove the

HDMI source, the unit will switch back to the VGA input.

b. You can force the unit to switch to the other input without removing any cables

by disabling the source video that is currently being displayed. For example: if you

have active sources connected to both inputs, and the HDMI input is currently

selected, by pressing (Fn+F8 twice) on the HDMI laptop, the video output will be

disabled, and the ASW-WP will select the VGA input. To return to the HDMI input,

press (Fn+F8 twice) to enable the video output. Depending on the laptop

manufacturer, this operation may alter slightly.

2. Contact Closure Inputs – By connecting momentary switches to the contact closure inputs

(see p.9) you can create push-button control of the input selection on the ASW-WP.

a. When using “Auto-switching with manual override” (p8, Fig.1) , the unit will

function as described in the “Auto” section above, but pressing one of the override

buttons will cause the unit to switch to the selected input. If there is no video

signal connected to the selected input, you will experience a black video screen.

b. When using “Manual switching mode” (p8, Fig. 2), the unit will only switch when

the button that corresponds to the input selection is pressed. If no video is present

on the selected input, you will experience a black video screen.

3. RS232 – By connecting the RS232 port of the HDBaseT receiver to a 3

rd

party control

system, serial commands can perform switching functions, as well as provide greater

information about the units status. RS232 control can be used simultaneously with

“Auto” and “Contact Closure” operation, but not when using the Display Control

functionality.

LED Indicators