Twisted Pair Output

The ASW-WP includes an HDBaseT Lite extender output.

When used in conjunction with compatible HDBaseT

receivers (see Tech Specs), the signal may be transmitted

up to 60m (200’) away. Additionally, the user may

connect via RS232 to the HDBaseT receiver, and control

the ASW-WP. Connection should be made using Cat6

unshielded or shielded cable. Please terminate both

ends using EIA/TIA-568B crimp pattern, as shown in this

diagram.

Contact Closure Inputs

The ASW-WP includes dry contact closure (C.C.) inputs to allow different types of manual

switching. These C.C. inputs are intended to be connected directly to relays or switches. To

activate, simply short the associated terminal to the “GND” terminal. The ASW-WP ships from

the factory with a jumper in place between the “AUTO”, and “GND” terminals; this should remain

in place if you wish the unit to switch automatically when a video signal is present. Normally

open, momentary switches should be used.

Fig. 1 – Auto-switching with

manual override.

Fig. 2 – Manual switching

mode.