Display Control Commands

Description

Command

Response

Turn Display Control ON

DFG1<CR><LF>

No response

Turn Display Control OFF

DFG0<CR><LF>

No response

Store the ON command for

Display Control (xx = up to 20

characters)

DON(xx)<SP><CR><LF>
Example:
DONpwron<SP><CR><LF>

No response

Store the OFF command for

Display Control (xx = up to 20

characters)

DOF(xx)<SP><CR><LF>
Example:
DOFpwroff<SP><CR><LF>

No response

Store the input select command

for Display Control (xx = up to 20

characters)

DIS(xx)<SP><CR><LF>
Example:
DIShdmi1<SP><CR><LF>

No response

Store the time between power

on and input select commands

(xxx = time in seconds – 3

characters)

DDC(xxx)<CR><LF>
Example for 5 sec.:
DDC005<CR><LF>

No response

Store the “No signal” timeout

value (xxx = time in minutes – 3

characters)

DNS(xxx)<CR><LF>
Example for 30 min.:
DNS030<CR><LF>

No response

Disable the “No signal” timeout

DNS000<CR><LF>

No response

Store the “No activity” timeout

value (xxx = time in hours – 3

characters)

DNA(xxx)<CR><LF>
Example for 3 hours:
DNA005<CR><LF>

No response

Disable the “No activity” timeout

DNA000<CR><LF>

No response

Store the display baud rate

DBR(x)<CR><LF>

Where:

1 = 115200

2 = 57600

3 = 19200

4 = 9600

No response

16