Programming row unit alarm levels, Programming row unit alarm levels -7, 7 kpm iii monitor operation – Kinze 3110 Mounted Planter Rev. 7/14 User Manual

Page 81

Advertising
background image

TM

Model 3110

M0244-01

9/12

5-7

KPM III Monitor Operation

Status

Plant

About

Setup Mode

Configuration:

Front / Rear

1. General Settings

2. Seed Meter Settings

3. Row Unit Alarm Levels

4. Setup Data Logging

5. Configure Planter Monitor

6. Add New Muxbus Sensors

7. Add Single Interplant Row

8. Select Speed Sensor

9. Sensor Setup

Logdata

Seed Meter Settings

Cancel

OK

Meter Type

Crop Type

Seeds per rev

Interplant

Vacuum

Meter Sprocket

teeth

28

Corn/Popcorn

39

Enabled

Enabled

Disabled

Seed Size

10

nominal 10, min 0, max 31

STEP 9

(If Applicable) Turn knob or use arrow keys to

highlight “Interplant”. Press knob or Enter key to

display Interplant drop down menu.

STEP 10

Turn knob or use arrow keys to highlight “enable” or

“disable” and press the knob or Enter key.

STEP 11

When all changes have been made, highlight “OK”

and press knob or Enter key to return to “Setup

Mode” screen.

STEP 2

To set alarm thresholds for whole planter, turn knob

or use arrow keys to highlight “[Whole Planter]” line.

Press key next to desired threshold. When desired

threshold is specified for all row units, press F6 key

next to “Done”.

NOTE: Only configured rows appear on screen.

To set alarm thresholds for all rows in one section, highlight

desired section. Press key next to desired threshold. When

desired threshold is specified for all row units, press F6 key next

to “Done”.

To set alarm thresholds for individual rows, highlight desired row.

Press key next to desired threshold. When desired threshold is

specified for all row units, press F6 key next to “Done”.

To disable row unit alarm, highlight desired section or individual

row. Press F4 key next to “Disable”. When alarm is desired

again highlight disabled section or row. Press key next to desired

threshold.

To enter threshold not listed, highlight desired section or individual

row. Press F5 key next to “Other”. Press knob or Enter key and

a drop down key pad appears. Turn knob or use arrow keys to

highlight first digit of desired number and press knob. Number

displays in “Enter Alarm Threshold” line. Highlight next digit of

the number and press knob. Number displays in the line. When

correct number is displayed, press Enter key to return to “Set

Alarm Threshold” screen. Turn knob or use arrow keys to advance

to “OK”. Press knob or Enter key to accept threshold levels.

Status

Plant

About

Setup Mode

Configuration:

Effective row spacing: 15.0

Front / Rear

1. General Settings

2. Seed Meter Settings

3. Row Unit Alarm Levels

4. Setup Data Logging

5. Configure Planter Monitor

6. Add New Muxbus Sensors

7. Add Single Interplant Row

8. Select Speed Sensor

9. Sensor Setup

10.Calibrate Speed Sensor

Logdata

10%

50%

Disable

Other

Done

Rear Row 1 50%
Rear Row 2 50%

Rear Row 4 50%
Rear Row 5 50%
Rear Row 6 50%
Rear Row 7 50%

Rear Row 8

50%

Front Row 1 50%
Front Row 2 50%
Front Row 3 50%
Front Row 4 50%

70%

Row Unit Alarm Levels

[Whole Planter]

Rear Row 3 50%

PROGRAMMING ROw UNIT ALARM LEVELS

Row Unit Alarm Levels allow thresholds for seed rate alarms to

be set. Default is 50% or Average. If average population drops

below 50% for a given row a seed rate alarm is generated for

that row unit. The alarm threshold can be set to 70%, 50%, 0% or

disabled, or any custom percentage for any row.

NOTE: when alarm threshold is disabled for any row no seed

rate alarm will be generated.

Alarm thresholds can be set for whole planter, any planter section,

or individual rows.

NOTE: A section is a set of rows driven by one or more

shafts, designated to a single shaft sensor.

STEP 1

Select ‘‘3. Row Unit Alarm Levels’’ by turning knob or

using arrow keys. Press knob or Enter key to display

highlighted item.

10%

50%

Disable

Other

Done

Rear Row 1 50%
Rear Row 2 50%

Rear Row 4 50%
Rear Row 5 50%
Rear Row 6 50%
Rear Row 7 50%

Rear Row 8

50%

Front Row 1 50%
Front Row 2 50%
Front Row 3 50%
Front Row 4 50%

70%

Row Unit Alarm Levels

[Whole Planter]

Rear Row 3 50%

Set Alarm Threshold

Enter Alarm Threshold

Cancel

OK

0