Plant screens, Planting setup, Rev. 5/14 – Kinze ISOBUS Electronics Package (3000 Series) Rev. 5/14 User Manual

Page 26: 1on 2 on 3 on 4 on

Advertising
background image

M0246

ISOBUS

20

Rev. 5/14

TM

PLANT SCREENS

Tap the pages button to toggle through the plant screens.

F

PAGE

2 OF 4

3:00 PM

ON

F

PAGE

2 OF 4

E

J

G

CORN

A

CONTROL

10

B

POPULATION

32.1

ON

OFF

TC

PLANTER

4

8

12

16

20

24

28

32

36

40

44

60%

0%

100%

120%

seeds

/acre

POPULATION

32,100

SPACING

6

in

ACCURACY

99

%

SINGULATION

93

SKIPS

%

4

%

DOUBLES

3

%

SECTIONS

1

ON

2

ON

3

ON

4

ON

SPEED

5.5

AREA

MPH

120

acres

ACRE / HOUR

40

80%

2/2

C

JUMPSTART

G

UNLOCK

SECTION

3:00 PM

ON

F

PAGES

E

J

A

CONTROL

DOWNFORCE

DEPTH

NORM

2.5

10

3 of 4

G

CROP TYPE

CORN

B

POPULATION

32.1

ON

OFF

GPS

ALARM-5

PLANTER

4

8

12

16

20

24

28

32

36

40

44

ROW SCAN - #2

34,000

SINGULATION ACCURACY

seeds

/acre

18.2 in

seeds

/acre

seeds

/acre

97

%

SKIPS

1

%

DOUBLES

2

%

HIGH ROW - #1

34,000

SINGULATION ACCURACY

98

%

SKIPS

0

%

DOUBLES

2

%

LOW ROW - #3

26,500

SINGULATION ACCURACY

98

%

SKIPS

2

%

DOUBLES

0

%

VACUUM

BULK FILL PRESSURE

12

in

60%

0%

100%

120%

80%

C

JUMPSTART

G

UNLOCK

SECTION

F

PAGE

2 OF 4

F

PAGE

3 OF 4

Planter ON/OFF is the master on/off switch for the planter. This switch will turn clutches and the hydraulic drive on
and off.

Population displays a large readout of the average seed population as well as seed spacing and the population
accuracy.

NOTE: Population accuracy = 100% + % of doubles - % of Skips.

Singulation displays a large readout of the average singlulation as a percentage as well as the skips and doubles.

NOTE: Singlulation is a measurement of how well the seed meter is working.

NOTE: Singlulation accuracy = 100% - % of doubles - % of Skips.

Speed displays the miles per hour, along with how many acres planted per hour, and the area.

Population Bar Graph represents one row per line. The green line is the target rate. Red bars indicate when the
population is above or below the specified threshold. See Population Monitoring to adjust thresholds.

vacuum displays vacuum level.

Bulk Fill Pressure displays the pressure level of the bulk fill system.

Row Scan displays a large readout of seed population for individual rows as well as singulation accuracy, skips and
doubles. This box will rotate through all rows changing every 5 seconds.

Section Control Buttons are used to turn sections on and off manually. For example, if the section control button on
the main screen is turned OFF, the sections can be turned on manually here. If the section control button on the main
screen is turned ON, the sections can be turned off manually.

Planting Setup