PNEUMATIC dOwN FORCE (PdP)

In the Pneumatic Down Force settings screen, the PSI to Force Formula and Low Down Force Threshold can be
adjusted. The PDP pressure sensor can also be zeroed.

Zeroing down Force Sensor
1.

Make sure there is no pressure in the air bags.

2.

Press the Zero button on the Pneumatic Down Force Settings screen.

3.

The readout to the left of the zero button should now read 0.

Note: do not change Force to PSI formula unless instructed by a Kinze service representative.

Prev

1. Select item below

Low down force
alar m threshold

5

lbs

PSI to Force
For mula

4.000 lb/psi

Zero pressure
offset

0

Z e r o