Population monitoring – Kinze ISOBUS Electronics Package (3000 Series) Rev. 5/14 User Manual

Page 38

Advertising
background image

M0246

ISOBUS

32

Rev. 5/14

TM

POPULATION MONITORING

In the Population Monitoring settings screen, high/low population alarm thresholds can be set as well as the low
singulation threshold and alarm response time. You can choose to set the population monitoring thresholds to be
universal for all rows at the main screen, or select monitoring specific to each row by selecting the By Row button on
the right.

By Row is used to scroll through each row and set individual population monitoring thresholds.

high Population Threshold displays a percentage above the target population that will trigger an alarm on the
screen.

Low Population Threshold displays a percentage below the target population that will trigger an alarm on the screen.

Low Singulation Threshold displays a percent singulation (seed meter accuracy) that will trigger the singulation data
cell to turn red.

Alarm Response displays how long it will take before these alarms are activated and will appear on the screen.

Use Global can be check marked so the same settings will be used for all rows. Uncheck for each row to be set
individually.

Settings

Use this button to

change settings by row

Advertising