Planter is turning off early:
The look-ahead or turn off time is too long. Measure the distance from where you would like it to shut off and where it
did shut-off. Then enter your information into the equation below:

d = Distance of the gap in inches

v = Tractor speed in miles/hour

0.057d/v = Time

Decrease the turn off time by the value you get for time. Recheck after adjustment.

Planter is turning off late:
The look-ahead or turn off time is too short. Measure the distance from where you would like it to shut off and where it
did shut-off. Then enter your information into the equation below:

d = Distance of the overlap in inches

v = Tractor speed in miles/hour

0.057d/v = Time

Increase the turn off time by the value you get for time. Recheck after adjustment.

Planter is turning on early:
The look-ahead or turn on time is too long. Measure the distance from where you would like it to turn on and where it
did turn on. Then enter your information into the equation below:

d = Distance of the overlap in inches

v = Tractor speed in miles/hour

0.057d/v = Time

Decrease the turn on time by the value you get for time. Recheck after adjustment.

Planter is turning on late:
The look-ahead or turn on time is too short. Measure the distance from where you would like it to turn on and where it
did turn on. Then enter your information into the equation below:

d = Distance of the gap in inches

v = Tractor speed in miles/hour

0.057d/v = Time

Increase the turn on time by the value you get for time. Recheck after adjustment.

NOTE: It is important that you drive a consistent speed in and out of preplanted areas and boundaries to
ensure accuracy of the shut-offs. See your Task Controller’s operators manual for more information about
adjusting offsets and look aheads.