dIAGNOSTICS

PMM voltage displays the voltage going to the PMM. The average voltage should be between 12 and 14 volts.

Muxbus 1 Power displays the power going to the sensors connected to Muxbus 1 or A. The average voltage should
be between 12 and 14 volts.

Muxbus 1 Signal displays the signal voltage for sensors connected to Muxbus 1 or A. The voltage will vary based on
how many messages are being sent.

Muxbus 2 Power displays the power going to the sensors connected to Muxbus 2 or B. The average voltage should
be between 12 and 14 volts.

Muxbus 2 Signal displays the signal voltage for sensors connected to Muxbus 2 or B. The voltage will vary based on
how many messages are being sent.

CAN high and Low ISOBUS displays the voltage on the CANbus that connects the display and PMM. The voltage for
each should be between 2 and 2.6 volts.

CAN high and Low Local displays the voltage on the CANbus that connects the PCM and PMM. The voltage for
each should be between 2 and 2.6 volts.

Implement Switch will display ON when implement switches are on and OFF when implement switches are off.

Rate Control Speed displays the speed of the hydraulic drive shaft sensor.

Rate Control valve Current displays how much current is going to the flow control valve. The more current applied,
the faster the hydraulic motor should turn.

hS Status displays the status of the control valve.

LS Status displays the status of the control valve.

Section Control and Seed Count have their own information screens, which are explained on the next page.

Section Control

Seed Counts