Drive control & communication – Lenze smd Series Drives User Manual

Page 20

Advertising
background image

RG-SDMOD 16

Drive Control & Communication

5.4.2 Operational Status - Register #26

Table 11 lists the Operational Status (Register #24 byte D3L or Register #26 DL)

Table 11: Operational Status

Bit

Parameter

0

FAULT LOCKOUT

1

FAULT

2

START PENDING

3

STOP

4

DC BRAKE

5

RUN AT 0Hz

6

RUN

7

ACCEL

8

DECEL

9

CURRENT LIMIT

10

DECEL OVERRIDE

11

LOWER TRANSISTORS SWITCHING ON

12

OFF

13

INHIBIT

5.4.3 Actual Rotational Direction - Registers #24 & 27

Table 12 lists the Actual Rotational Direction (Register #24 byte D4H or Register #27 DH).

Table 12: Actual Rotational Direction

Setting

Direction

0

FORWARD

1

REVERSE

5.4.4 Control Mode - Registers #24 & 27

Table 13 lists the Control Mode (Register #24 byte D4L or Register #27 DL).

Table 13: Control Mode

Control Mode Speed Source

Control Source

Program Source

0

Analog

Terminal

Keypad

1

c40

Terminal

Keypad

2

Analog

Terminal

LECOM

3

LECOM

LECOM

LECOM

4

Analog

Terminal

Remote Keypad

5

c40

Terminal

Remote Keypad

6

Analog

Remote Keypad

Remote Keypad

7

c40

Remote Keypad

Remote Keypad

8

Analog

Terminal

Modbus

9

c40

Terminal

Modbus

10

Analog

Modbus

Modbus

11

c40

Modbus

Modbus

Advertising