21 RG-SDMOD

Drive Control & Communication

Parameter No.

1

smd Register #

(hexadecimal

representation)

Parameter Name

Range of Adjustment

2,

Modbus value (decimal value)

Factory

Default

PV400

PV507

C08

57 (39H)

57 (39H)

Configuration
Relay Output

0 Ready
1 Fault
2 Motor is running
3 Motor is running - CW rotation
4 Motor is running - CCW rotation
5 Output frquency = 0Hz
6 Frequency setpoint reached
7 Threshold (C17) exceeded
8 Current limit reached
9 Feedback within min/max alarm range
10 Feedback outside min/max alarm range

1

C09

58 (3AH)

58 (3AH)

Network Address

1 - 247

1

C10

59 (3BH)

59 (3BH)

Minimum Output Freq.

0 - 2400 (0.0 - 240 Hz)

0.0 Hz

C11

60 (3CH)

60 (3CH)

Minimum Output Freq.

75 - 2400 (7.5 - 240 Hz)

50.0 Hz

C12

61 (3DH)

61 (3DH)

Acceleration Time

0 - 9990 (0.0 - 999 sec)

5.0 sec

C13

62 (3EH)

62 (3EH)

Deceleration Time

0 - 9990 (0.0 - 999 sec)

5.0 sec

C14

63 (3FH)

63 (3FH)

Operating Mode

0 Linear with Auto Boost
1 Square Law with Auto Boost
2 Linear with Constant V

min

Boost

3 Square Law with Constant V

min

Boost

2

C15

64 (40H)

64 (40H)

V/f Reference Point

250 - 9990 (25.0 - 999 Hz)

50.0 Hz

C16

65 (41H)

65 (41H)

V

min

Boost

0 - 400 (0.0 - 40.0%)

4.0%

C17

66 (42H)

66 (42H)

Frequency Threshold

0 - 2400 (0.0 - 240 Hz)

0.0 Hz

C18

67 (43H)

67 (43H)

Chopper Frequency

0 4kHz
1 6kHz
2 8kHz
3 10kHz

2

C21

68 (44H)

68 (44H)

Slip Compensation

0 - 400 (0.0 - 40.0%)

0.0%

C22

69 (45H)

69 (45H)

Current Limit

30 - 150%

150%

C24

70 (46H)

70 (46H)

Accel Boost

0 - 200 (0.0 - 20.0%)

0.0%

C31

71 (47H)

Analog Input Deadband

0 Deadband Enabled
1 Deadband Disabled

0

C34

71 (47H)

72 (48H)

Configuration
Analog Input

0 0...10V
1 0...5V
2 0...20mA
3 4...20mA
4 4...20mA Monitored

0

C36

72 (48H)

73 (49H)

Voltage (DCB)
DC Injection Brake

0 - 500 (0.0 - 50.0%)

4.0%

C37

73 (49H)

74 (4AH)

Fixed Setpoint 1 (JOG1)

0 - 9990 (0.0 - 999)

20.0 Hz

1 = The drive's programming code number; 2 = Selections in