Drive control & communication, 2 parameter list – Lenze smd Series Drives User Manual

Page 24

Advertising
background image

RG-SDMOD 20

Drive Control & Communication

6.2 Parameter List

Parameter No.

1

smd Register #

(hexadecimal

representation)

Parameter Name

Range of Adjustment

2,

Modbus value (decimal value)

Factory

Default

PV400

PV507

C01

51 (33H)

51 (33H)

Setpoint and Control
Source

Speed

Control

Program

0 Analog Terminal

Keypad

1 c40

Terminal

Keypad

2 Analog Terminal

LECOM

3 LECOM LECOM

LECOM

4 Analog

Terminal

Remote Keypad

5 c40

Terminal

Remote Keypad

6 Analog

Remote Keypad Remote Keypad

7 c40

Remote Keypad Remote Keypad

8 Analog Terminal

Modbus

9 c40

Terminal

Modbus

10 Analog Modbus

Modbus

11 c40

Modbus

Modbus

0

C02

52 (34H)

52 (34H)

Load Lenze setting

0 No action/loading complete
1 Load 50Hz Defaults
2 Load 60Hz Defaults
3 Load OEM Defaults
4 Translate compatible EPM
NOTE: Drive must be in OFF or Inhibit state to change

0

CE1
CE2
CE3

53 (35H)
54 (36H)
55 (37H)

53 (35H)
54 (36H)

55 (37H

Configuration
Digital Inputs
E1, E2, E3

1 Activate fixed setpoint 1 (JOG1)
2 Activate fixed setpoint 2 (JOG2)
3 DC Braking (DCB)
4 Direction of Rotation
5 Quick Stop
6 CW Rotation
7 CCW Rotation
8 UP
9 DOWN
10 TRIP set
11 TRIP reset
12 Accel/decel 2
13 Deactivate PI
14 Activate fixed PI setpoint 1
15 Activate fixed PI setpoint 2

CE1 = 1
CE2 = 4
CE3 = 3

1 = The drive's programming code number; 2 = Selections in

bold are for

smd models with PV507 only.