17 RG-SDMOD

Drive Control & Communication

5.4.5 Speed Command Source - Registers #24 & 28

Table 14 lists the Speed Command Source (Register #24 byte D5H or Register #28 DH).

Table 14: Speed Command Source

Setting

Source

0

ANALOG FREQ.

1

PRESET c40

2

PRESET 1

3

PRESET 2

4

PRESET 3

5

MOP SPEED

6

SERIAL SPEED

5.4.6 Speed Reference Status - Registers #24 & 28

Table 15 lists the Speed Reference Status (Register #24 byte D5L or Register #28 DL).

Table 15: Speed Reference

Setting

Status

0

SERIAL SPEED REFERENCE

1

LOCAL SPEED REFERENCE

5.4.7 Present Fault - Registers #24 & 29

Table 16 lists the Present Fault (Register #24 byte D6H of Register #29 DH)

Table 16: Present Fault

Setting Fault

Display

Setting Fault

Display

0

NO FAULT

14

INTERNAL FAULT 5

F5

1

OUTPUT (TRANSISTOR) FAULT

OC1

15

INTERNAL FAULT 6

F6

2

HIGH DRIVE TEMPERATURE

OH

16

INTERNAL FAULT 7

F7

3

HIGH DC BUS VOLTAGE

OU

17

INTERNAL FAULT 8

F8

4

LOW DC BUS VOLTAGE

LU

18

INTERNAL FAULT 9

F9

5

THERMAL OVERLOAD

OC6

19

INTERNAL FAULT o

Fo

6

CONTROL FAULT

CF

20

SINGLE PHASE FAULT

SF

7

EXTERNAL FAULT

EEr

21

INCOMPATIBILITY FAULT

cF

8

SERIAL COMMUNICATION FAILURE

FC5

22

DYNAMIC BRAKE OVERHEATED

dF

9

START ERROR

LC

23

REMOTE KEYPAD FAULT

JF

10

INTERNAL FAULT 1 (EPM)

F1

24

COMMUNICATION FAULT

FC3

11

INTERNAL FAULT 2

F2

25

EARTH FAULT

OC2

12

INTERNAL FAULT 3

F3

26

CONFIGURATION FAULT

CFG

13

INTERNAL FAULT 4

F4

Advertising