E94AYCEN communication manual (Ethernet)
Technical data
Protective insulation
16
L
EDS94AYCEN EN 9.0 - 09/2012
4.2
Protective insulation
Danger!
Dangerous electrical voltage
If Servo Drives 9400 are used on a phase earthed mains with a rated mains
voltage ≥ 400 V, protection against accidental contact is not guaranteed
without external measures.
Possible consequences:
• Death or severe injuries
Protective measures:
• If protection against accidental contact is required for the control terminals
of the drive and for the connections of the plugged-in device modules, ...
– a double isolating distance must exist.
– the components to be connected must be provided with the second
isolating distance.
Note!
The protective insulation provided in Servo Drives 9400 is implemented in
accordance with EN 61800-5-1.