9 parameter reference, C00615 | resp. to imp. device config, C00636 | resp. to new module in mxi1 – Lenze E94AYCEN User Manual

Page 54: Parameter reference, Parameter reference ( 54), Supplemented, Communication, E94aycen communication manual (ethernet), 9parameter reference

Advertising
background image

E94AYCEN communication manual (Ethernet)

Parameter reference

Parameters of the standard device that are relevant to communication

54

L

EDS94AYCEN EN 9.0 - 09/2012

9

Parameter reference

This chapter supplements the parameter list and the table of attributes in the software

manual and in the »Engineer« online help for the Servo Drive 9400 by the parameters of

the E94AYCEN communication module (Ethernet).

9.1

Parameters of the standard device that are relevant to communication

In this chapter communication-relevant parameters of the Servo Drive 9400 are listed in

numerically ascending order.

C00615

C00636

Software manual/»Engineer« online help for the Servo Drive 9400
Here you will find general information on parameters.

Parameter | Name:

C00615 | Resp. to imp. device config.

Data type: UNSIGNED_32

Index: 23960

d

= 5D98

h

Response to impermissible device configuration
Selection list

1 Fault
3 Quick stop by trouble
4 Warning Locked
6 Information
0 No Response

Subcodes

Lenze setting

Info

C00615/1

0: No Response

Reserved

C00615/2

0: No Response

Resp. to imp. module in MXI1

C00615/3

0: No Response

Resp. to imp. module in MXI2

C00615/4

0: No Response

Reserved

C00615/5

0: No Response

Reserved

;

Read access ; Write access … CINH … PLC STOP … No transfer

Parameter | Name:

C00636 | Resp. to new module in MXI1

Data type: UNSIGNED_32

Index: 23939

d

= 5D83

h

Response if a new module has been plugged into module slot 1 of the standard device.
Selection list

(Lenze setting printed in bold)

1 Fault
6 Information
5 Warning
4 Warning Locked
3 Quick stop by trouble
0 No Response

;

Read access ; Write access … CINH … PLC STOP … No transfer