2 electrical installation, 1 emc-compliant wiring, Electrical installation – Lenze E94AYCEN User Manual

Page 21: Emc-compliant wiring, E94aycen communication manual (ethernet)

Advertising
background image

EDS94AYCEN EN 9.0 - 09/2012

L

21

E94AYCEN communication manual (Ethernet)

Installation

Electrical installation

5.2

Electrical installation

5.2.1

EMC-compliant wiring

In typical systems, standard shielding is sufficient for Ethernet cables.
However, in environments with a very high level of interference, EMC resistance can be

improved by additionally earthing the cable shield on both sides.
For this observe the following notes:

1. The distance between the additional earthing and the Ethernet plug depends on the

module slot and is as follows:
– Approx. 10 cm for the upper slot (MXI1)
– Approx. 20 cm for the lower slot (MXI2)

2. Measure the appropriate distance along the cable and, starting from this point, remove

2 cm of the cable's plastic sheath.

3. Fasten the cable shield onto the shield sheet of the Servo Drive 9400.

[5-3]

EMC-compliant wiring

Documentation for the standard device, control system, system/machine
Observe the notes and wiring instructions contained in this documentation.

E94YCXX008

A Fastening on the shield sheet of the Servo Drive

9400

B Outgoing Ethernet cable at X216

C Incoming Ethernet cable at X215

D Communication module in slot MXI1 of the

Servo Drive 9400