7 parameter data transfer, Parameter data transfer, Description in chapter – Lenze E94AYCEN User Manual

Page 38

Advertising
background image

E94AYCEN communication manual (Ethernet)

Parameter data transfer

38

L

EDS94AYCEN EN 9.0 - 09/2012

7

Parameter data transfer

The PC (client) used for setting parameters and the controller (server) communicate with

one another by exchanging data telegrams via the Ethernet. The parameter data are

contained in the user data area of the data telegram.

 Parameters are set, for instance, when the system is initially adjusted during

commissioning or when the material of the production machine is changed.

 The parameter data are transmitted as SDOs (Service Data Objects) and confirmed by

the receiver, i.e. the transmitter receives a feedback whether the transmission was

successful.
The SDOs provide for the write and read access to the object directory in the controller.

 The transmission of the parameter data usually is not time-critical.
 The parameter data are saved in Lenze devices as "codes".

Via the codes, for instance operating parameters, motor data or diagnostics

information can be set.

[7-1]

Data communication according to the client/server model

Note!

With regard to the writing access on parameter data, observe that the changes

carried out are not stored automatically in the controller.
In order to save changed parameter settings with mains failure protection, carry

out the device command C00002 = "11: Save start parameters".

Advertising